Danfoss condensing units are widely used in various commercial and industrial refrigeration needs due to their high efficiency, reliability, easy installation and maintenance.
Main features and advantages High efficiency and energy saving: Danfoss condensing units use advanced scroll compressors or piston compressors, optimize system design, improve heat exchange efficiency, reduce energy consumption and failure rate.
Safety and reliability: All products have undergone strict electrical strength tests to ensure safety during operation. The unit is equipped with a variety of protection devices, such as high and low voltage protection, phase sequence protection, and voltage and current protection, to further ensure the stable operation of the equipment.
Environmental protection and energy saving: The use of high-efficiency refrigerants such as R404A and R134a complies with strict global energy regulations, and provides alternative refrigeration solutions such as R290 and R1234yf to meet different environmental protection requirements.
Low maintenance cost: The unit has a compact design, easy maintenance, and a long service life, which reduces long-term operating costs.
Intelligent design: Some models are equipped with condensing fan control, which automatically adjusts the fan speed according to the condensing pressure to further save energy.
Application scenarios Danfoss condensing units are suitable for a variety of commercial and industrial scenarios, including milk cooling tanks, cold storage, fermentation rooms, canteens, hospitals, etc.
Its efficient and reliable performance makes it excel in these fields, helping users save energy and maintenance costs and improve production efficiency.

Danfoss condensing units are widely used in various commercial and industrial refrigeration needs due to their high efficiency, reliability, easy installation and maintenance.
Main features and advantages High efficiency and energy saving: Danfoss condensing units use advanced scroll compressors or piston compressors, optimize system design, improve heat exchange efficiency, reduce energy consumption and failure rate.
Safety and reliability: All products have undergone strict electrical strength tests to ensure safety during operation. The unit is equipped with a variety of protection devices, such as high and low voltage protection, phase sequence protection, and voltage and current protection, to further ensure the stable operation of the equipment.
Environmental protection and energy saving: The use of high-efficiency refrigerants such as R404A and R134a complies with strict global energy regulations, and provides alternative refrigeration solutions such as R290 and R1234yf to meet different environmental protection requirements.
Low maintenance cost: The unit has a compact design, easy maintenance, and a long service life, which reduces long-term operating costs.
Intelligent design: Some models are equipped with condensing fan control, which automatically adjusts the fan speed according to the condensing pressure to further save energy.
Application scenarios Danfoss condensing units are suitable for a variety of commercial and industrial scenarios, including milk cooling tanks, cold storage, fermentation rooms, canteens, hospitals, etc.
Its efficient and reliable performance makes it excel in these fields, helping users save energy and maintenance costs and improve production efficiency.

Application Guidelines Technical specifications
50 Hz R404A
Model |
HP |
Nominalcooling capacity* |
Powerinput* | Efficiency* | Swept volume | Displacement | Oil charge | Net weight(with oil) | ||
| W | BTU/h | KW |
COP W/W |
EER Btu/h/W | cm3/ rev | m3/h | Litres | kg | ||
| MLZ015 |
2 | 3300 | 11300 | 1.75 | 1.89 | 6.45 | 33.8 | 5.9 | 1.1 | 31 |
| MLZ019 |
2.5 | 4500 | 15400 | 2.16 | 2.06 | 7.03 | 43.5 | 7.6 | 1.1 | 31 |
| MLZ021 | 3 | 4700 | 16000 | 2.27 | 2.08 | 7.10 | 46.2 | 8.0 | 1.1 | 31 |
| MLZ026 | 3.5 | 5800 | 19800 | 2.9 | 2.00 | 6.83 | 57.1 | 9.9 | 1.1 | 31 |
| MLZ030 | 4 | 7100 | 24200 | 3.35 | 2.11 | 7.20 | 68.8 | 12.0 | 1.6 | 41 |
| MLZ038 | 5 |
8400 | 28700 | 3.86 | 2.19 | 7.47 | 81.0 | 14.1 | 1.6 | 41 |
| MLZ042 | 5.5 | 9500 | 32400 | 4.72 | 2.02 | 6.89 | 93.1 | 16.2 | 1.6 | 41 |
| MLZ045 | 6 | 10200 | 34800 | 4.81 | 2.11 | 7.20 | 98.6 | 17.2 | 1.6 | 41 |
| MLZ048 | 7 | 11100 | 37900 | 5.17 | 2.14 | 7.30 | 107.5 | 18.7 | 1.6 | 41 |
| MLZ058 | 7.5 | 13000 | 44400 | 6.08 | 2.13 | 7.27 | 126.0 | 21.9 | 2.7 | 47 |
| MLZ066 | 9 | 15100 | 51500 | 7.01 | 2.15 | 7.34 | 148.8 | 25.9 | 2.7 | 47 |
| MLZ076 | 10 | 17300 | 59000 | 9.93 | 2.18 | 7.44 | 162.4 | 28.3 | 2.7 | 47 |
R134a and R22 are also applicable. Please consult the merchant to obtain specific parameters.
Application Guidelines Technical specifications
50 Hz R404A
Model |
HP |
Nominalcooling capacity* |
Powerinput* | Efficiency* | Swept volume | Displacement | Oil charge | Net weight(with oil) | ||
| W | BTU/h | KW |
COP W/W |
EER Btu/h/W | cm3/ rev | m3/h | Litres | kg | ||
| MLZ015 |
2 | 3300 | 11300 | 1.75 | 1.89 | 6.45 | 33.8 | 5.9 | 1.1 | 31 |
| MLZ019 |
2.5 | 4500 | 15400 | 2.16 | 2.06 | 7.03 | 43.5 | 7.6 | 1.1 | 31 |
| MLZ021 | 3 | 4700 | 16000 | 2.27 | 2.08 | 7.10 | 46.2 | 8.0 | 1.1 | 31 |
| MLZ026 | 3.5 | 5800 | 19800 | 2.9 | 2.00 | 6.83 | 57.1 | 9.9 | 1.1 | 31 |
| MLZ030 | 4 | 7100 | 24200 | 3.35 | 2.11 | 7.20 | 68.8 | 12.0 | 1.6 | 41 |
| MLZ038 | 5 |
8400 | 28700 | 3.86 | 2.19 | 7.47 | 81.0 | 14.1 | 1.6 | 41 |
| MLZ042 | 5.5 | 9500 | 32400 | 4.72 | 2.02 | 6.89 | 93.1 | 16.2 | 1.6 | 41 |
| MLZ045 | 6 | 10200 | 34800 | 4.81 | 2.11 | 7.20 | 98.6 | 17.2 | 1.6 | 41 |
| MLZ048 | 7 | 11100 | 37900 | 5.17 | 2.14 | 7.30 | 107.5 | 18.7 | 1.6 | 41 |
| MLZ058 | 7.5 | 13000 | 44400 | 6.08 | 2.13 | 7.27 | 126.0 | 21.9 | 2.7 | 47 |
| MLZ066 | 9 | 15100 | 51500 | 7.01 | 2.15 | 7.34 | 148.8 | 25.9 | 2.7 | 47 |
| MLZ076 | 10 | 17300 | 59000 | 9.93 | 2.18 | 7.44 | 162.4 | 28.3 | 2.7 | 47 |
R134a and R22 are also applicable. Please consult the merchant to obtain specific parameters.